Mode of Packing |
2.5 kg, 15 kg. |
Definition |
It is an alkyd resin based, air drying, glossy topcoat paint |
Color |
According to colour card. |
Uses of... |
It can be safely used on surface every kind of metal machine such as tractor, trailer, auto radiator, agriculture, garden and steel household goods etc. |
Specifications |
It is an industrial top coat paint that dries quickly, is resistant to climatic conditions and impacts, has a high adhesion ability to metal surfaces. |
Technical Features |
Type of Resin : Alkyd resin
Viscosity (KU)(25 °C) : 85 ± 5
Specific Gravity (g/ml) (20 °C) : 1.40 ± 0.05
Solid Content (by weight) (%) : 71 ± 2
Glossy ( 60° - Gloss) : Min. 80
Flash Point ( °C ) : <21
Theoretical Coverage : 9 m²/lt (60 µ dry film thickness)
Practical Coverage : 0,095 - 0,110 lt/m² (one coat), 0,135 - 0,155 kg/m² (one coat)
Recommended number of coats : Two coats
Drying Time (20 °C) : Touch dry : 10 - 15 min. , Dust free : 20 - 30 min. , Dry through : 1 - 2 hours
Thin Down Ratio : It is thinned with 20 - 25% Merbolin Rapid / Hammerton Thinner.
|
Application 1 |
a ) New metal surface : Application surface must be clean and free from rust and dust. The surface should be primered with Merbolin Rapid Primer. b ) Old Painted Surface : Old and blistered paint on surface must be clean and all surface should be sandpapered and levelled with putty as regional area. Application surface must be clean and dry. |
Application 2 |
Merbolin Industrial Paint - Rapid is applied directly on metal surface or on primered surface when it thin with 20 - 25% Merbolin Rapid/ Hammerton Thinner. |
Storage Conditions |
It should be storaged in original and closed containers at 5 - 35 °C temperatures. It should be protected from extreme heat and moisture. |
Important Notices |
Paint must be mixed before the use.
The ambient temperature should be between 5 - 35 °C at the time of application
Application tools must be cleaned with Merbolin Rapid / Hammerton Thinner, after the application,.
After the application, the painted surface must be protected during
3 days, from chemical and physical factors.
Paint doesn’t empty into drains.
Application procedures defined above should be strictly observed.
|