Merbolin Cellulosic Sanding Sealer

Mode of Packing 0.750 l, 2.500 l and 15 l.
Definition It is a nitro cellulose based sanding sealer which is quick drying easy to sand.
Color Colourless, transparent.
Uses of... It can be safely used on all kind of wooden surface for filling to pore and obtaining the smooth surface.
Specifications It is quick drying easy to sand and doesn’t change the surface nature. Due to filling the surface, the surface doesn’t absorb the topcoat varnish and to save the time and topcoat material.
Technical Features

Type of Resin : Urethane alkyd resin
Viscosity (KU)(25°C) : 80 ± 5
Specific Gravity (g/ml) (20°C) : 0.93 ± 0.03
Solid Content (by weight) (%) : 27 ± 1
Flash Point ( °C ) : < 21
Theoretical Coverage : 10 m ² / lt (30 µ dry film thickness )
Practical Coverage : 0,065 - 0,095 lt/m² ( one coat ) 0,060 0,090 kg/m² ( one coat )
Recommended number of coats : one or two coats.
Drying Time (20°C) : Touch dry : 15 - 30 min. Dust free : 1.5 - 2 hours
Thin Down Ratio : It is thinned with 20-25% Merbolin Cellulosic Thinner.

Application 1 The application surface must be sound, dry and clean. . The wooden surfaces should be filled with Merbolin Cellulosic Sanding Sealer, after drying, the surface must be emerized and cleaned
Application 2 The varnish must be mixed before the use. Depending on the application conditions, Merbolin Cellulosic Glossy Varnish is thinned with 20-25 % Merbolin Cellulosic Thinner. Merbolin Cellulosic Glossy Varnish should be applied as two or three cross coats, allowing 1-2 hours between the coats.
Storage Conditions It should be storaged in original and closed containers at 5-35°C temperatures for three years. It should be protected from extreme heat and moisture.
Important Notices

The varnish must be mixed before the use.
The ambient temperature should be between 5 - 35 ° C at the time of application
Application tools must be cleaned with Merbolin Synthetic Thinner, after the application,.
After the application, the varnished surface must be protected during 3 days, from chemical and physical factors.
The varnish doesn't empty into drains.
Application procedures defined above should be strictly observed.The varnish must be mixed before the use.
The ambient temperature should be between 5-35 ° C at the time of application
Application tools must be cleaned with Merbolin Synthetic Thinner, after the application,.
After the application, the varnished surface must be protected during 3 days, from chemical and physical factors.
The varnish doesn't empty into drains.
Application procedures defined above should be strictly observed.


DANGER WARNINGS

H225 Highly flammable liquid and vapour.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H361d Suspecting of causing harm to the unborn child.
H336 May cause dizziness or lightheadedness.
H373 May cause organ damage in case of long or repetitive exposure.
EMERGENCY WARNINGS

P101 Keep the package and the label if you need medical advice.
P102  Keep out of reach of children
P103  Read the label before using. 
P210 Keep away from heat/sparks/flames/hot surfaces. – Smoking is forbidden.
P241 Use explosion proof electrical/ventilating/ignition materials.
P303+P361+P353 IN CASE OF SKIN (or hair) CONTACT: Instantly remove/take off all contaminated clothing. Rinse your skin with water/shower.
P305+P351+P338 IN CASE OF EYE CONTACT: Carefully rinse with water for several minutes. Remove them if you are wearing contact lenses and they are easy to remove. Continue rinsing.
P405 Keep under lock and key.
P501 Dispose of the content/container in accordance with local/regional/national/international legislations.