Mode of Packing |
I. Component : 15 kg / II. Component (Hardener): 5 kg |
Definition |
It is a epoxy resin based transparent primer paint, which has two components. |
Color |
Colourless |
Uses of... |
It can be safely used under the epoxy paint on concrete surface. |
Specifications |
It is applied on concrete surface under the epoxy paint. The surface is saturated by this product which obtains strongly to adhesion between paint and surface. |
Technical Features |
Type of Resin : Epoxy Resin / Polyamide Hardener
Specific Gravity (g/ml) (20 °C) : 0.90 ± 0.05
Glossy : Semi matt.
Solid Content (by weight) (%) : 23 ± 1
Solid Content (by volume) (%) : 20 ± 1
Flash Point (°C) : 22
Heat Resistance (Dry) (°C) : 150
Theoretical Coverage : 5 - 6 m²/lt ; 6 m²/kg (35 µ dry film thickness)
Practical Coverage : 4 - 7 m²/kg (25 - 50 µ dry film thickness)
Mixing Ratio(by weight): I.Component:75/ II.Component(Hardener):25
Pot Life (20 °C) : 8 - 12 hours.
Dry film thickness (one coat application) : 15 - 25 µ
Drying Time(20 °C- Relative Humidity 65%):First drying: 1 - 2 hours, Drying : 2 - 4 hours, Second coat application: 24 hours, Full hardening : 7 days
Thin Down Ratio : Due to it produced at application viscosity, it is not need thinner.
|
Application 1 |
All application surface must be clean, dry and free from oil. |
Application 2 |
Epoxy Sealer and hardener components should be mixed well observe to mixing ratio. 5 - 10 minutes waited after components mixing, Merbolin Epoxy Sealer is applied on surface with brush or roller as one or two coats, allowing 24 hours between the coats. |
Storage Conditions |
It should be storaged in original and closed containers at 5 - 35 °C temperatures for two years. It should be protected from extreme heat and moisture. |
Important Notices |
Two components must be mixed well.
The mixture should be prepared enough as small parts. The mixing ratio should be considered for paint wastage.
The ambient temperature should be between 5 - 35 °C at the time of application
Application tools must be cleaned with Merbolin Epoxy Thinner, after the application,.
Paint doesn't empty into drains.
Application procedures defined above should be strictly observed.
|