Mode of Packing |
17 kg. |
Definition |
It is a silicone resin based heat resistance primer paint, which includes aluminium pigment. |
Color |
Metallic Grey. |
Uses of... |
It can be safely used on metal surface which heated until 400 °C. |
Specifications |
It adheres well to surface, resists to heat until 400 °C. It is anticorrosive primer paint which endures catodic protection and gives aluminium colour. |
Technical Features |
Type of Resin : Silicone resin
Viscosity (KU)(25 °C) : 95 -100
Specific Gravity (g/ml) (20 °C) : 2.50 ± 0.05
Solid Content (by weight) (%) : 81 ± 1 Solid Content (by volume) (%) : 50 ± 1
Glossy ( 60° - Gloss ) : Matt
Flash Point ( °C ) : < 21
Heat Resistance (Dry) ( °C ) : 400
Theoretical Coverage : 24 m²/lt; 10m²/kg (20µ dry film thickness )
Practical Coverage : 4 – 8 m²/kg (20 - 40µ dry film thickness)
Recommended dry film thickness : 20 - 30 µ
Recommended number of coats : one or two coats.
Drying Time (20 °C):Touch drying :30 - 60 min. Drying:8 - 10 hours, Second coat application : 24 hours, Full Hardening : 24 hours later to working temperature.
Thin Down Ratio : It should be thinned with Merbolin Heat Resistance Paint Thinner 5% by weight.
|
Application 1 |
The surface should be cleaned by sand blasting Sa 2½. All application surface must be clean, dry and free from rust and old paint layers. |
Application 2 |
Merbolin Heat Resistance Aluminium Primer Paint should be thinned with Merbolin Heat Resistance Paint Thinner 5% by weight and applied with brush or paint gun. If second coat application is necessary, should be waited 24 hours between the coats. |
Storage Conditions |
It should be storaged in original and closed containers at 5 - 35 °C temperatures. It should be protected from extreme heat and moisture. |
Important Notices |
Primer paint must be mixed well before the use.
The ambient temperature should be between 5 - 35 °C at the time of application
Application tools must be cleaned with Merbolin Heat
Resistance Paint Thinner, after the application,.
After the application, the painted surface must be protected during 24 hours, from chemical and physical factors.
The primer paint doesn’t empty into drains.
Application procedures defined above should be strictly observed
|