Merbolin Solventfree Epoxy Sealer

Mode of Packing I. Component : 10 kg / II. Component (Hardener): 6 kg
Definition It is a solventfree epoxy resin based, transparent primer which has two components.
Color Transparent
Uses of... It can be safely used as a primer on concrete surface before solventfree epoxy self levelling coating application.
Specifications It is applied on concrete surface under the solventfree epoxy self levelling coating. The surface is saturated by this product which obtains strongly to adhesion between coating and surface.
Technical Features

Type of Resin : Epoxy Resin / Polyamine Hardener
Specific Gravity (g/ml) (20 °C) : 1.10 ± 0.05
Glossy : Gloss
Solid Content (by weight) (%) : 99 ± 1
Solid Content (by volume) (%) : 98 ± 1
Flash Point ( °C ) : Nonflammable
Heat Resistance (Dry) (°C) : 140
Theoretical Coverage : 5 m²/lt; 4 m²/kg (200 µ dry film thickness)
Practical Coverage : 3 - 4,5 m²/kg (150 - 250 µ dry film thickness)
Mixing Ratio (by weight) : I. Comp.: 62.5 / II. Comp.(Hardener): 37.5
Pot Life (20 °C) : 30 - 40 minutes.
Drying Time (20 °C- Relative Humidity 85%): First drying: 1 - 2 hours, Drying : 5 - 6 hours, Second coat application : 10 - 12 hours,                Full hardening : 7 days
Thin Down Ratio : Thinner addition is not recommended.

Application 1 All application concrete surface must be sound, clean, dry and free from oil. If oil on the surface, which should be cleaned by chemical cleaning materials. If oil absorbed by the surface, which is cleaned by burninng and if oil inside the concrete which is breaked and repaired.
Application 2 Solventfree Epoxy Sealer and hardener components should be mixed well observe to mixing ratio. 0.250 kg of the mixture of solventfree epoxy sealer should be applied on 1m² surface. Merbolin Solventfree Epoxy Sealer is applied 200 µ dry film thickness on the clean surface with by brush or roller. Second coat application is recommended on porous surface.
Storage Conditions It should be storaged in original and closed containers at 5 - 35 °C temperatures for two years. It should be protected from extreme heat and moisture.
Important Notices

Two components must be mixed well.
The mixture should be prepared enough as small parts. The mixing ratio should be considered for paint wastage.
The ambient temperature should be between 5 - 35 °C at the time of application
Application tools must be cleaned with Merbolin Epoxy Thinner, after the application,.
Paint doesn't empty into drains.
Application procedures defined above should be strictly observed.


DANGER WARNINGS

H315 Causes skin irritation.
H319 Causes serious eye irritation.
H317 Causes allergic skin reactions.
H302+H312 Harmful in contact with skin or if swallowed.
H411 Long-lasting toxic effect in aquatic environments. 
H314 Causes serious skin burns and eye damage.
H361fd Suspected of damaging fertility.Suspecting of causing harm to the unborn child.
EMERGENCY WARNINGS

P101 Keep the package and the label if you need medical advice.
P102  Keep out of reach of children
P103  Read the label before using. 
P260 Do not breathe dust, vapor, mist, gas, smoke, spray.
P261 Avoid breathing dust, vapor, mist, gas, smoke, spray.
P280 Use protective gloves/protective clothing/glasses/mask. 
P303+P361+P353 IN CASE OF SKIN (or hair) CONTACT: Instantly remove/take off all contaminated clothing. Rinse your skin with water/shower.
P305+P351+P338 IN CASE OF EYE CONTACT: Carefully rinse with water for several minutes. Remove them if you are wearing contact lenses and they are easy to remove. Continue rinsing.
P310 Call the NATIONAL POISON CENTER IMMEDIATELY ON 114 or doctor/physician. 
P405 Keep under lock and key.
P321 Special medical response required (see label) 
P362 Remove contaminated clothing and wash before reuse.
P501 Dispose of the content/container in accordance with local/regional/national/international legislations.