Mode of Packing |
15 lt. |
Definition |
It is an acrylic copolymer resin based, matt, heat insulation ceiling paint containing ceramic additives in its structure. |
Color |
White |
Uses of... |
It can be safely used on interior ceiling surfaces of gypsum, plaster, concrete for decorative, heat insulation and protection purposeful. |
Specifications |
Due to having photocatalytic properties, the paint surface always appears clear and fresh. It is water based, matt ceiling paint which has high opacity, water permeability, anti-condensation properties, cleaned easily, odourless and environment friendly. It has flame retardent properties and good mechanical resistance. It provides energy saving under the every kind of weather conditions at all seasons. It saves up 30 to 35% energy by reducing heating and cooling expenses. |
Technical Features |
Type of Resin : Acrylic copolymer
Viscosity (KU)(25 °C) : 134 ± 3
Specific Gravity (g/ml) (20°C) : 1.25 ± 0,03
Solid Content (by weight) (%) : 68 ± 2 Solid Content (by volume) (%) : 50 ± 2
Glossy ( 85° - Gloss ) : 7 ± 3
pH : 8.00 - 9.00
Theoretical Coverage : 16 m² /lt ; 13 m²/kg (30 µ dry film thickness)
Practical Coverage : 0,070 - 0,100 lt/m² ( one coat )
0,090 - 0,125 kg/m² ( one coat )
Recommended number of coats : Two coats.
Drying Time (20 °C) : Drying : 2 - 3 hours
Full drying: 24 hours
Thin Down Ratio : 20% (with water - by volume)
|
Application 1 |
All application surfaces must be sound, dry and clean old painted, blistered and dirty ceiling surface must be cleaned by scratching and puttied with Merbolin Interior Putty to take sound and smooth surface. After putty application, the surface should be primered with Merboizolan Insulation Primer as one coat. Ambient temperature must be between 5 °C and 35 °C during application. |
Application 2 |
2 - 3 hours after primer application, Merbotherm Heat Insulation Ceiling Paint, which is applied with brush or roller, is thinned with 20% water. It should be applied as two coats, allowing 2-3 hours between the coats. |
Storage Conditions |
It should be storaged in original and closed containers at 5 - 35 °C. It should be protected from extreme heat, moisture and frost. |
Important Notices |
Paint must be mixed before the use.
The ambient temperature should be between 5 - 35 °C at the time of application
Application tools must be cleaned with water, after the application,.
After the application, the painted surface must be protected during
3 days, from chemical and physical factors.
Paint doesn't empty into drains.
Application procedures defined above should be strictly observed.
|